10.4 Fault indicators for
RFT9739
Fault indicators control milliamp outputs and the frequency/pulse output
when the RFT9739 cannot accurately measure process variables.
For Version 2 and earlier RFT9739 transmitters, fault indicators can be
configured using the ProLink program (see below). Later versions of the
RFT9739 require setting of hardware switches inside the transmitter.
See the instruction manual that was shipped with the transmitter.
To use fault indicators to troubleshoot the flowmeter, see
Section 7.2
(page 56).
Example:
Given
: Primary milliamp and frequency/pulse outputs indicate the
mass flow rate.
Problem
: To compensate for noise from a slow-acting valve,
approximately two seconds of damping need to be added to the
existing 0.8 second of internal damping on mass flow as indicated by
an RFT9739.
Solution
: Enter a value of 2.00 into the Damp text box under Milliamp 1.
The RFT9739 damps the frequency/pulse output at a filter coefficient
of 0.8 second. After rounding down to the nearest programmed
coefficient of the secondary filter, the RFT9739 damps the primary
milliamp output at approximately 0.8 + 1.6 seconds, or 2.4 seconds.