Using ProLink
®
Software with Micro Motion
®
Transmitters
127
Configure Menu:
Transmitter Outputs
Configure Menu:
Transmitter Information
Configure Menu: EventsView Menu: Status
Configure Menu:
Characterize
Configure Menu:
Transmitter Variables
12 Configure Menu: Events
12.1 Overview
Assigning Event 1 or Event 2 to an RFT9739 output changes the
function of the output. If associated with an event, a milliamp output or
the control output functions as an event indicator. An event indicator
operates in ON/OFF states. It switches from one state to the other when
the process reaches a programmed setpoint.
• As an event indicator, a milliamp output switches from one
programmed current level to another programmed current level when
the process reaches the setpoint.
• As an event indicator, the control output switches from 0 V to +15 V
or vice versa when the process reaches the setpoint.
IFT9701, IFT9703, RFT9712, and RFT9729 outputs cannot be
configured for events.
To assign an event to an output:
1. Open the Configure menu, then choose Transmitter Outputs to open
the Configure Outputs dialog box.
2. Open the list box beside Milliamp 1, Milliamp 2, or Control, then
select Event 1 or Event 2 as the output variable.
3. Configure event parameters as described in
Section 12.2
.
4. If Milliamp 1 or Milliamp 2 was configured as an event indicator,
configure milliamp current levels as described in
Section 12.3
.
12.2 Configuring event
parameters
After assigning Event 1 or Event 2 to a milliamp output or the control
output, use the Configure Events dialog box to configure event
parameters.
Open the Configure menu, then choose Events. The Configure Events
dialog box appears as shown in
Figure 12-1
. Assign variables, alarms,
and setpoints to events as described on pages 128 and 130.